A lab dip is a small laboratory-dyed sample made to match a specified colour standard, usually for evaluation before bulk dyeing. It helps buyer and dye house agree the intended colour on an identified substrate. Cotton Incorporated’s Lab Dip Process describes requests specifying both colour and substrate, followed by comparison and, when necessary, further submissions.
Lab dip approval is not bulk production approval, colour fastness certification or validation of a production-scale dye recipe. It cannot guarantee every subsequent lot. For a South African brand ordering uniforms or coordinating overseas suppliers, the useful deliverable is a traceable decision—not an isolated message saying “looks good”.
Know Which Sample You Are Approving
These are working descriptions; names and approval authority vary between businesses. Establish the reference hierarchy rather than assuming every sample has equal status.
| Item | Role | What it does not establish |
|---|---|---|
| Lab Dip Sample | Identified laboratory submission for colour review | Acceptance of production fabric |
| Approved Colour Standard | Controlled target: physical swatch, authorised digital reference or agreed combination | That every supplier holds the same current version |
| Bulk Fabric Sample | Material taken from actual production, linked to its dye lot | Uniformity throughout all rolls or lots |
| Pre-Production Sample | Reference garment/sample reviewing specified materials, construction and appearance before a run | Approval of every later unit |
| Shade Band | Identified samples showing shade variation or an agreed acceptable range | Permission to supply any shade unless explicitly accepted |
| Production Lot | Identified production batch; record its relationship to dye lots and rolls | Interchangeability with other batches |
An approved lab dip may become a working production reference, but do not silently replace the original standard. Record which reference governs if the two differ.
Lock the Colour Standard and Fabric Substrate
Give the colour standard a sample ID, version and date. Record whether the authority is a physical colour swatch, controlled spectral data or another agreed reference. A colour name, photograph or ordinary screen RGB value alone does not reproduce the fabric’s physical appearance under all conditions. Proper digital colour communication is more than sending a screenshot.
The fabric substrate is the material receiving the dye. Specify fibre composition, weave/knit construction, preparation and intended finish. A cotton poplin submission is not automatically representative of a polyester knit, even when both are called navy. Structure, surface, dye system and finishing influence appearance and matching feasibility.
Datacolor’s colour-programme guidance highlights current standards, appropriate substrates, clear responsibilities and consistent supplier instructions. Check these before treating repeated submissions as evidence of poor dye-house competence.
Multiple rounds may be needed because a first submission misses depth or hue, a finish changes appearance, or comparison conditions were inconsistent. CottonWorks also notes adjustments during scale-up. Ask the supplier to investigate and resubmit; a buyer’s visual comment cannot identify a unique chemical or processing cause.
Evaluate Appearance Under Agreed Conditions
Compare standard and submission side by side using a documented viewing setup. Keep orientation, background, presentation and conditioning consistent. State which light sources govern approval and which are additional checks; do not select whichever makes the match look best.

Lighting and metamerism
D65 is a daylight reference; TL84/F11 represents a fluorescent lighting condition; A represents incandescent/tungsten lighting. An illuminant is a defined spectral reference, not simply any lamp with a similar-looking colour. Konica Minolta’s illuminants explanation distinguishes these uses and advises confirming the required application conditions.
Brands may specify other sources, including relevant LED conditions. There is no single light source that suits every apparel order. Datacolor’s lighting guidance explains why similar colour temperatures do not necessarily mean similar spectral output. Record the actual setup, not just “daylight checked”.
Metamerism means two materials match under one lighting condition but differ under another, as HunterLab explains. It is not simply one fabric changing appearance when you move rooms. Record the standard–sample difference under each specified source, especially when matching fabric with trims or other materials.
Spectrophotometers and ΔE
A spectrophotometer measures spectral response; software can calculate colour coordinates and differences under selected conditions. CIELAB describes L* lightness, a* green–red and b* blue–yellow. ΔE*ab measures distance in that space; CIEDE2000 uses a different colour-difference calculation, not a different fabric or a colour space.
Do not compare their numbers directly or write only “ΔE passed”. Identify formula, illuminant, observer, geometry, measurement mode and preparation. Datacolor’s CIELAB/CIE2000 explanation covers these distinctions. There is no fixed ΔE threshold suitable for every colour, textile and customer.
Record instrument identity/calibration status and applicable UV settings, backing, layers, orientation and repeated readings. Sample-presentation guidance explains how these affect results. Visual judgement and instrumental data must be reconciled under the agreed acceptance plan; a single number does not replace appearance assessment.
Use the relevant method—not a borrowed standard number
Checked on 26 October 2026: AATCC EP9-2025 concerns visual textile colour-difference evaluation; ISO 105-J01:1997, confirmed in 2024, addresses general surface-colour measurement principles; ISO/CIE 11664-6:2022 defines the CIEDE2000 calculation.
ISO 3664:2025 concerns graphic technology and photography viewing conditions, not blanket textile lab-dip acceptance. These public scopes are not complete operating instructions or universal buying tolerances. Identify the applicable procedure and edition separately from the customer’s acceptance criteria. Colour measurement is also distinct from resistance to washing or rubbing.
Copyable Lab Dip Approval & Supplier Handoff Card
Keep one controlled record per colour/substrate, with a new submission entry for each round. Attach physical sample references and reports rather than overwriting earlier decisions. Fields grouped below retain the information chain without requiring a particular software system.
| Field group | Fill in / attach |
|---|---|
| Parties and project | Buyer/brand: ___; supplier/dye house: ___; project/order reference: ___ |
| Fabric identity | Substrate/code: ___; fibre composition: ___; weave/knit construction: ___; weight/preparation/finish: ___ |
| Original colour standard | Standard sample ID: ___; version/date: ___; physical/digital authority and reference hierarchy: ___ |
| Submission identity | Submitted lab dip ID: ___; submission round: ___; option/version: ___ |
| Batch and date | Sample batch/date: ___; dye lot or laboratory reference, where available: ___ |
| Viewing conditions | Specified light source(s): ___; primary/secondary: ___; cabinet/setup, background, orientation and conditioning: ___ |
| Visual colour assessment | Difference from standard under each source: ___; reviewer: ___ |
| Instrumental measurement, if applicable | Instrument/calibration: ___; formula, illuminant/observer, geometry/mode: ___; UV/presentation/readings/report: ___ |
| Agreed tolerance / acceptance criteria | Quality agreement/version: ___; numerical and visual requirements: ___; decision authority: ___ |
| Deviation and buyer feedback | Observed deviation/source: ___; sample-specific buyer comments: ___ |
| Required revision | Requested colour direction/change: ___; supplier clarification/action: ___; resubmission reference: ___ |
| Approval decision | Status and scope: ___; conditions: ___; approved sample/version: ___; approver/date: ___ |
| Production reference | Reference handed to production: ___; bulk sample/dye-lot links: ___; separate release gate: ___ |
| Archive location | Physical standard/sample location: ___; controlled file/decision location: ___; supplier acknowledgement: ___ |
| Unknown information | Unknown / Requires Supplier Verification: ___; owner and next action: ___ |
Agree status meanings in advance. Approved accepts the named object within its stated scope. Approved with conditions must list conditions, their owner and whether progression is permitted. Revise and resubmit requests another identified sample; rejected declines that submission under the agreement. Pending clarification leaves the decision open because information is missing. These labels have no automatic global commercial effect.
Hypothetical Lab Dip Approval Example
Everything below—order, samples, dates, observations and decision—is Hypothetical / Illustrative, not a real supplier record or validated recipe.
Reference and request: An imaginary South African work-shirt buyer, Example Buyer, asks Example Dye House to develop slate blue for order SA-SH-01. The original physical target is STD-SL-01, version 1, dated 1 October 2026. Substrate CP150-v1 is specified as 100% cotton plain-weave poplin, nominal 150 GSM, with the agreed softening finish SF1 applied before evaluation. Neither party substitutes another base.
Conditions: Their hypothetical plan requires visual acceptance by the buyer’s designated colour lead under D65 and TL84 in the recorded cabinet setup, against STD-SL-01 v1. A/incandescent evaluation is not specified. Instrumental assessment is not required in this invented plan: ΔE is Not measured, not zero or “passed”. A real agreement requiring instrumental results would remain pending without them.
Round 1: Submission LD-SL-R1-A, laboratory batch LAB-04, dated 12 October 2026, is recorded as darker than the target under D65 and redder under TL84. Feedback: “Revise and resubmit LD-SL-R1-A: reduce depth relative to STD-SL-01 v1 under D65; reduce the red deviation under TL84. Retain CP150-v1/SF1 and submit a new ID.” The supplier investigates the formulation/process; no dye quantities are prescribed by the buyer.
Round 2 and decision: LD-SL-R2-B, laboratory batch LAB-07, dated 15 October 2026, is considered an acceptable visual match under both specified sources by the fictional colour lead. On 16 October the recorded decision is: “Approve colour appearance of LD-SL-R2-B only, on CP150-v1/SF1, against STD-SL-01 v1 under D65 and TL84.” No signature or numerical reading is invented.
Archive and handoff: Retain STD-SL-01 v1 and LD-SL-R2-B in physical archive CAB-02; store the request, both reviews and decision in controlled folder SA-SH-01/Colour/v2. Mark R1 superseded, not deleted. The supplier acknowledges the reference. Bulk dye-lot ID, bulk sample and production release remain Unknown / pending separate review. The original standard remains authoritative; R2-B is the approved working sample, not permission to change the target.
Turn Review Problems into Actionable Feedback
Possible causes below are questions to investigate—not diagnoses from eyesight alone.
| Review problem | Possible cause | Required evidence | Buyer feedback | Supplier next action |
|---|---|---|---|---|
| Too dark / light | Depth mismatch or presentation difference | Standard, setup and identified sample | State darker/lighter relative to the named target | Verify conditions; adjust and resubmit |
| Too red / yellow | Hue mismatch, lighting, dye system or finish | Per-source comparison; measurements if required | Identify hue direction and source | Investigate alternatives, not an assumed single cause |
| Match changes across lights | Potential metamerism or inconsistent setup | Same pair under agreed sources | Name where the pair diverges | Confirm sources and reassess matching |
| Standard versions disagree | Obsolete physical/digital reference | Both IDs, dates and file versions | Suspend comparison until target is confirmed | Obtain controlled current reference |
| Substrate differs | Wrong base, blend, construction or finish | Fabric codes/specifications | Request evaluation on agreed substrate | Resample or seek explicit scope change |
| Sample ID missing | Submission-control gap | Physical sample-to-record link | Decision pending identification | Relabel with traceable evidence |
| Rounds/options confused | Reused IDs or overwritten comments | Submission and response history | Name the exact round/option to revise | Reconcile log; issue distinct next ID |
| Final approval untraceable | Generic “OK”, lost sample or archive gap | Named sample, decision, conditions and approver | Request controlled confirmation before handoff | Restore evidence or resubmit for review |
Keep the Approval Chain Intact Through Bulk Review
Use this repeatable sequence; the diagram shows the record chain, not a factory dyeing recipe.

- Confirm the colour standard and substrate, including versions and finish.
- Agree viewing conditions and acceptance criteria, with decision authority.
- Request identified lab dip samples and record each round/option.
- Evaluate visual and instrumental colour difference where required.
- Record deviations against the named standard under each specified source.
- Issue actionable feedback without prescribing an unverified dye recipe.
- Review revised samples without losing previous submissions.
- Approve a specific version with an explicit scope or unresolved conditions.
- Archive samples, decisions and supplier acknowledgement.
- Verify bulk production against the agreed reference and separate release requirements.

Bulk shade control should identify dye lots and rolls, compare representative production samples and record any agreed shade band. Scale-up, finishing and lot variation can change appearance. Review affected references when the substrate, finish or process changes rather than carrying approval forward automatically. Our manufacturing approval-stage guide places material and pre-production decisions in the wider workflow.
Finally, appearance approval does not replace colour fastness reports, including relevant washing and rubbing evidence, or dimensional-change checks. Retain these as separate quality questions. Before handing over a colour, ensure the next team can identify the standard, approved sample, conditions and decision—and see what is still Unknown.
Sources
- Cotton Incorporated: Lab Dip Process, undated process demonstration.
- Datacolor: effective colour programmes, light sources, CIELAB/CIE2000 and sample measurement, undated technical guidance.
- Konica Minolta: Light Sources and Illuminants; HunterLab: Metamerism Index, undated explanations.
- AATCC EP9-2025, ISO 105-J01:1997, ISO/CIE 11664-6:2022 and ISO 3664:2025: public scopes/status checked 26 October 2026, not full operating procedures.

